Martin Audio MA NETCONTROL Guía de usuario Pagina 1

Busca en linea o descarga Guía de usuario para Redes Martin Audio MA NETCONTROL. Martin Audio MA NETCONTROL User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 31
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
The Martin Experience
MA-NET1 & MA Netcontrol
User’s Guide
All material © 2007. Martin Audio Ltd. Subject to change without notice.
Vista de pagina 0
1 2 3 4 5 6 ... 30 31

Indice de contenidos

Pagina 1 - MA-NET1 & MA Netcontrol

The Martin ExperienceMA-NET1 & MA NetcontrolUser’s GuideAll material © 2007. Martin Audio Ltd. Subject to change without notice.

Pagina 2 -

9Note: A separate, third-party network device must be accommodated in the system to create a LAN connection. This could raise reliability issues, p

Pagina 3 - Contents

10To establish a connection, use the following procedure: 1. In XP Home - Go to the START menu in the lower left corner, select “Connect to” and th

Pagina 4

114.4 Establishing a wired or wireless LAN connection It is recommended that you make your LAN connections using a network device (hub, switch or r

Pagina 5 - 1 Warnings

12This window allows selection of an amplifier con-figuration for loading into MA Netcontrol. The choices are: Uploading information from connecte

Pagina 6 - 2 Introduction

13If you are certain that subnets have been connected, this could indicate a problem with the Windows Firewall, a physical connection, or the networ

Pagina 7

145.3 Toolbars overview MA Netcontrol is organized around a set of views accessible by selecting buttons on the main toolbar. The different views ac

Pagina 8

15 Offline: When not connected to a physical subnet, editing of an offline configuration is possible in Edit mode. You may add devices, add groups

Pagina 9

16Each MA-NET1 may be configured for sequential power-up for all connected amplifiers in the Subnet (See the MA-NET1 Operation Manual). To access th

Pagina 10 - 4.3 TCP/IP setup

17use a slow left click, right click and choose Rename, or use the F2 key. Enter the new name for the device. Channels Channels may be renamed in t

Pagina 11

185.4.8 Reconnecting to a subnet If connection to a subnet is lost (e.g. due to accidental disconnection of network cable), a Reconnect dialog wind

Pagina 12

Operations Guide- MA-Net1 - Nomadlink/Ethernet Bridge MA Netcontrol - Network Control and Monitoring Software

Pagina 13

196.3.2 Selecting Operate and Edit modes You may select Operate and Edit modes using the dedicated buttons on the toolbar. Alternatively, you may s

Pagina 14 - Figure 8

206.4.2 Device view columns Figure 10 Device name A default device name is assigned when uploading data from the subnet, or when configuring a ne

Pagina 15 - 5.3 Toolbars overview

21DiP switch Match DIP switch Match is active only in the Online state and Operate mode. The indicator color represents the status of detected Physi

Pagina 16 - Power on/off

226.4.4 Matching to the physical subnet A transition from the Offline state in Edit mode to Online state automatically initiates the match function

Pagina 17

236.6 Group view 6.6.1 Overview Group View (Figure 13) is the primary view used for real-time operation and monitoring when a system configuration

Pagina 18

246.6.3 Group view fault and warning indicators (red) Fault condition for the Channel or Group (yellow) Warning condition for the Channel or Grou

Pagina 19 - 6 Reference Section

256.6.5 Group and Subnet warning and fault icons When expanded (see 6.6.2) the Group module indicates any current faults and warnings in any Group

Pagina 20

266.7.2 Subnet details The MA-NET1 Info tab displays information on the NomadLink Bridge and Network Controller controlling the subnet. Normally thi

Pagina 21

276.7.3 Device details The Match Device tab displays information on the match status (if any) between the configured device and data uploaded from t

Pagina 22

28 The Channel tab shows the level meter, temperature, and fault or warning indication. Solo and Mute button are active when the device is on and MA

Pagina 23 - 6.5 Channel view

2Contents 1 Warnings 4 2 Introduction 5 2.1 Hardware - MA-NET1 Nomadlink/Ethernet Bridge 5 2.1.1 Mains connection

Pagina 24 - 6.6 Group view

296.8.2 Functionality Tree View provides quick access to details for any channel or subnet. Double click on the channel or subnet icon to bring up t

Pagina 25

307 MA-NET1 warranty Martin Audio electronic products are warranted against manufacturing defects in materials or craftsmanship over a period of 3

Pagina 26 - 6.7 Details view

36.4.4 Matching to the physical subnet 22 6.4.5 Device Sorting 22 6.5 Channels View

Pagina 27 - 6.7.2 Subnet details

41 Warnings The lightning symbol within a triangle is intended to alert the user to the presence of un-insulated “dangerous voltage” within the am

Pagina 28 - 6.7.3 Device details

52 Introduction 2.1 Hardware - MA-NET1 The MA-NET1 NomadLink/Ethernet Bridge acts as a subnet master for up to 60 units of networked NomadLink-ready

Pagina 29 - 6.8 Tree view

6Rear panel detail 2.1.1 Mains connection To reduce the risk of fire or electrical shock, do not expose this apparatus to rain or moisture and

Pagina 30 - 6.9 Locking Functions

7This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may caus

Pagina 31 - 7 MA-NET1 warranty

83.2 Software installation Install the application by running the MA Netcontrol_Installer-1.2.0.exe (or later) installer. Follow the instructions a

Comentarios a estos manuales

Sin comentarios